Test ID BLOD1413 Plasminogen Activity, Plasma

Useful For

Evaluating patients with ligneous conjunctivitis (strong association with homozygous plasminogen deficiency)

 

Evaluating fibrinolysis, in combination with other components of the fibrinolytic system (fibrinogen, tissue plasminogen-activator-inhibitor, and d-dimers)

Specimen Type

Plasma Na Cit


Ordering Guidance


Coagulation testing is highly complex, often requiring the performance of multiple assays and correlation with clinical information. For that reason, we suggest ordering AATHR / Thrombophilia Profile, Plasma and Whole Blood.



Necessary Information


If priority specimen, mark request form, give reason, and request a call-back.



Specimen Required


Specimen Type: Platelet-poor plasma

Collection Container/Tube: Light-blue top (3.2% sodium citrate)

Submission Container/Tube: Plastic vial (polypropylene preferred)

Specimen Volume: 1 mL

Collection Instructions:

1. For complete instructions, see Coagulation Guidelines for Specimen Handling and Processing.

2. Centrifuge, transfer all plasma into a plastic vial, and centrifuge plasma again.

3. Aliquot plasma into separate plastic vial leaving 0.25 mL in the bottom of centrifuged vial.

4. Freeze plasma immediately (no longer than 4 hours after collection) at -20° C or, ideally at -40° C or below.

Additional Information:

1. A double-centrifuged specimen is critical for accurate results as platelet contamination may cause spurious results.

2. Each coagulation assay requested should have its own vial.


Reject Due To

Gross hemolysis Reject
Gross lipemia Reject
Gross icterus Reject

Specimen Minimum Volume

0.5 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Plasma Na Cit Frozen 14 days

Day(s) Performed

Monday through Friday

Report Available

3 days

Method Name

Chromogenic

Performing Laboratory

Mayo Clinic Laboratories in Rochester

CPT Code Information

85420

Reporting Name

Plasminogen Activity, P

Reference Values

75-140%

Test Classification

This test has been modified from the manufacturer's instructions. Its performance characteristics were determined by Mayo Clinic in a manner consistent with CLIA requirements. This test has not been cleared or approved by the US Food and Drug Administration.

Secondary ID

9079
Sanford Laboratories - Sioux Falls/Rapid City Additional Information:

SANFORD LABORATORY INTERFACE BUILD INFORMATION

Result Code  Result Code Description 
18602 Plasminogen Activity, P