Test ID BLOD0128 Liver/Kidney Microsome Type 1 Antibodies, Serum

Useful For

Evaluation of patients with liver disease of unknown etiology

 

Evaluation of patients with suspected autoimmune hepatitis

Specimen Type

Serum


Specimen Required


Supplies: Sarstedt Aliquot Tube, 5 mL (T914)

Collection Container/Tube:

Preferred: Serum gel

Acceptable: Red top

Submission Container/Tube: Plastic vial

Specimen Volume: 0.5 mL

Collection Instructions: Centrifuge and aliquot serum into a plastic vial.


Reject Due To

Gross hemolysis Reject
Gross lipemia Reject
Gross icterus OK
Heat treated Reject

Specimen Minimum Volume

0.4 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Refrigerated (preferred) 21 days
  Frozen  21 days

Day(s) Performed

Monday, Wednesday, Friday

Report Available

2 to 4 days

Method Name

Enzyme-Linked Immunosorbent Assay (ELISA)

Performing Laboratory

Mayo Clinic Laboratories in Rochester

CPT Code Information

86376

Reporting Name

Liver/Kidney Microsome Type 1 Ab, S

Reference Values

≤20.0 Units (Negative)

20.1-24.9 Units (Equivocal)

≥25.0 Units (Positive)

Reference values apply to all ages.

Test Classification

This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.

Forms

If not ordering electronically, complete, print, and send 1 of the following with the specimen:

-Gastroenterology and Hepatology Test Request (T728)

-General Request (T239)

Secondary ID

80387

Testing Algorithm

For more information see First-Line Screening for Autoimmune Liver Disease Algorithm.

Sanford Laboratories - Sioux Falls/Rapid City Additional Information:

SANFORD LABORATORY INTERFACE BUILD INFORMATION

Result Code  Result Code Description 
13069 Liver/Kidney Microsome Type 1 AB, S