Test ID PATH1022 Conventional Pap Smear
Specimen Type/Requirements
Pre-smeared slide
Note: Specimen must be spread thinly across slide and properly fixed with 95% alcohol.
Collection Instructions:
- Label charged slide with 2 unique patient identifiers (name, MRN, or DOB) using Chemical Resistant Slide marker.
- Obtain specimen from patient using desired ThinPrep collection device.
- Spread specimen thinly across slide quickly.
- Immediately place slide in 95% alcohol to fix sample. (DO NOT use spray-fixative)
- NOTE: Improperly fixed or smeared slides may result in nondiagnostic results due to air drying or excessive sample thickness.
- Send slide in 95% alcohol transport vial to laboratory.
Specimen Volume
Preferred Volume | 1 pre-smeared slide |
---|---|
Minimum Volume | 1 pre-smeared slide |
Stability/Transport
Room Temperature | 7 days in 95% alcohol | Preferred for transport |
---|---|---|
Refrigerated | Not Acceptable | |
Frozen | Not Acceptable |
Performed Test Frequency
Monday through Friday
Report Available
5 days from receipt into testing laboratory
Methodology
Pap stain on pre-smeared slide
Performing Lab
Sioux Falls Sanford Health Pathology Clinic
CPT
88164