Sign in →

Test ID BLOD1742 HIV-1/HIV-2 RNA Detection, Serum

Specimen Type/Requirements

Gold top (Serum w/gel) tube - Serum

Red top (Serum w/out gel) tube - Serum

 

Specimen should be centrifuged and separated within 2 hours of collection.

 

Test may be affected by gross hemolysis.

Specimen Volume

Specimen Volume

 Preferred Volume     1.5 mL   
 Minimum Volume     0.75 mL   

Stability/Transport

 Room Temperature     1 day     
 Refrigerated     5 days       
 Frozen     6 weeks     Preferred for transport   

Performed Test Frequency

Monday, Wednesday, Friday

Report Available

48 hours

Additional Information

Due to the potential cross-reactivity between some NAT assays and certain lentiviral vector-based CAR-T cell therapies, clinicians should exercise caution when ordering and interpreting HIV testing in patients who have received CAR-T cell therapy. Some lentiviral CAR-T vectors contain a target region of the test, which can lead to false positive HIV-1 results.

Performing Lab

Sanford Laboratories Sioux Falls

CPT

87538, 87535

Interface Build Information

SANFORD LABORATORIES INTERFACE BUILD INFORMATION

 Result Code     Result Code Description   
 29279  HIV-1 RNA
 29280  HIV-2 RNA