Test ID BLOD1203 Protein Electrophoresis Serum Reflex to Immunofixation

AKA

SPEP, Immunofix

Specimen Type/Requirements

Gold top (Serum w/gel) tube - Serum 

Red top (Serum w/out gel) tube - Serum

 

Fasting is preferred.  Plasma is not acceptable.  Serum should be removed from cells within 4 hours of collection.

 

Test is affected by hemolysis.  Test is not affected by lipemia.

Specimen Volume

 Preferred Volume     5.0 mL   
 Minimum Volume     2.0 mL   

 

Stability/Transport

 Room Temperature     Not Acceptable     
 Refrigerated     7 days     Preferred for transport   
 Frozen     30 days     

 

Performed Test Frequency

Monday through Friday

Additional Information

Test includes:  Serum Total Protein and Serum Protein Electrophoresis with Pathologist Interpretation.


If protein spike is present, the test will automatically reflex to an Immunofixation at an additional charge.

Methodology

Biuret, Electrophoresis, Immunofixation if needed

Performing Lab

Sanford Laboratories Sioux Falls

CPT

84165, Reflex 86334