Test ID BLOD0926 Antibody Screen
AKA
ABS, Indirect Coombs
Specimen Type/Requirements
Pink top (EDTA) tube - Whole Blood (preferred)
Lavender top (EDTA) tube - Whole Blood (2 tubes)
For obstetric patients, draw specimen before the administration of Rh Immune Globulin. During extremely cold or hot weather, separate plasma from cells and send both specimens.
See Blood Bank Specimen Labeling Policy
Test is affected by hemolysis. Test is not affected by lipemia.
Specimen Volume
Preferred Volume | 10.0 mL |
---|
Stability/Transport
Room Temperature | Not Acceptable | |
---|---|---|
Refrigerated | 3 days | Preferred for transport |
Frozen | Not Acceptable |
Performed Test Frequency
Monday through Sunday
Additional Information
If positive, antibody identification will be performed at an additional fee.
Methodology
To be determined by testing location
Performing Lab
Sanford Laboratories Sioux Falls
CPT
86850