Sign in →

Test ID BLOD0926 Antibody Screen

AKA

ABS, Indirect Coombs

Specimen Type/Requirements

Pink top (EDTA) tube - Whole Blood (preferred)

Lavender top (EDTA) tube - Whole Blood (2 tubes)

 

For obstetric patients, draw specimen before the administration of Rh Immune Globulin.  During extremely cold or hot weather, separate plasma from cells and send both specimens.

See Blood Bank Specimen Labeling Policy

 

Test is affected by hemolysis.  Test is not affected by lipemia.

Specimen Volume

 Preferred Volume     10.0 mL   

 

Stability/Transport

 Room Temperature     Not Acceptable     
 Refrigerated     3 days     Preferred for transport   
 Frozen     Not Acceptable     

 

Performed Test Frequency

Monday through Sunday

Additional Information

If positive, antibody identification will be performed at an additional fee.    

Methodology

To be determined by testing location

Performing Lab

Sanford Laboratories Sioux Falls

CPT

86850