Test ID BLOD0838 Anemia Panel
Specimen Type/Requirements
Gold or Red top (Serum w/gel or w/out gel) tube - Serum
and
Lavender top (EDTA) tube - Whole Blood
Protect serum from light. Separate serum from cells within 1 hour of collection.
Test is affected by hemolysis and lipemia.
Specimen Volume
Serum:
Preferred Volume | 6.0 mL |
---|---|
Minimum Volume | 2.8 mL |
EDTA Whole Blood:
Preferred Volume | 4.0 mL |
---|---|
Minimum Volume | 1.0 mL |
Stability/Transport
Serum:
Room Temperature | Not Acceptable | |
---|---|---|
Refrigerated | 3 days | Preferred for transport |
Frozen | Greater than 7 days |
EDTA Whole Blood:
Room Temperature | Not Acceptable | |
---|---|---|
Refrigerated | 3 days | Preferred for transport |
Frozen | Not Acceptable |
Performed Test Frequency
Monday through Sunday
Additional Information
This test includes Ferritin, Iron, Iron Binding Capacity, Reticulocyte Count, Vitamin B12 and Folate.
Methodology
Chemiluminescence,Ferrous/dye complex, Ferrozine and Automated Cell Counter
Performing Lab
Sanford Laboratories Sioux Falls
CPT
82728, 83540, 83550, 85046, 82607, 82746