Sign in →

Test ID BLOD0655 Glucose Gestational Diabetic Screen 1 Hr

Specimen Type/Requirements

Grey top (Sodium Fluoride) tube - Plasma (preferred for Sanford Sioux Falls)

Light Green top (Lithium Heparin w/gel) tube - Plasma  
Gold top (Serum w/gel) tube - Serum (preferred for Sanford Rapid City)

Red top (Serum w/out gel) tube - Serum

 

Give 50 gm oral glucose load and draw pt 1 hour later.  Patient does not have to fast; can be done any time of day.  Prompt separation from cells is essential.
 

Test is affected by gross hemolysis.  Test is not affected by lipemia. 

Specimen Volume

 Preferred Volume     1.0 mL   
 Minimum Volume     0.6 mL   

 

Stability/Transport

 Room Temperature     24 hours     
 Refrigerated     7 days     Preferred for transport   
 Frozen     3 months     

 

Performed Test Frequency

Monday through Sunday

Methodology

Enzymatic Hexokinase

Performing Lab

Sanford Laboratories Sioux Falls
Sanford Laboratories Rapid City

CPT

82950