Sign in →

Test ID BLOD0516 Rabies Antibody Endpoint

Specimen Type

Serum


Specimen Required


Specimen Type: Serum

Collection Container/Tube:

Preferred: Red top

Acceptable: Serum gel tube

Specimen Volume: 1 mL

Collection Instructions:

1. Centrifuge and aliquot 1 mL of serum into a plastic vial.

2. Send refrigerate.

Note: Collection date is required.


Specimen Minimum Volume

0.5 mL

Specimen Stability Information

Specimen Type Temperature Time
Serum Refrigerated (preferred) 14 days
  Frozen  60 days

Reject Due To

Gross hemolysis Reject
Gross lipemia Reject
Bacterial contamination Reject

Day(s) Performed

Monday, Wednesday, Thursday

Report Available

12 to 16 days

Method Name

Serum Neutralization Fluorescent Antibody

Reporting Name

Rabies RFFIT Endpoint, S

Performing Laboratory

RFFIT/K-State Rabies Laboratory Manhattan/K-State Innovation Center

Secondary ID

90330

CPT Code Information

86382

Reference Values

Reportable range is 0.1 IU/mL to 15.0 IU/mL

Less than 0.1 IU/mL: Below detection limit

 

In humans a result of 0.5 IU/mL or higher is considered an acceptable response to rabies vaccination according to the World Health Organization (WHO) guidelines; see WHO and Advisory Committee on Immunization Practices documents for additional guidance.

Sanford Laboratories - Enterprise Additional Information:

SANFORD LABORATORY INTERFACE BUILD INFORMATION

 Result Code     Result Code Description   
 5550  Rabies Antibody