Test ID BLOD0182 Histamine Plasma
Specimen Type
Plasma EDTASpecimen Required
Collection Container/Tube: Lavender top (EDTA)
Submission Container/Tube: Plastic vial
Specimen Volume: 1 mL Plasma
Collection Instructions:
1. Immediately place specimen on ice.
2. Centrifugation should be performed within 20 minutes of collection at 900 rpm for 10 minutes at 4° C.
3. Carefully remove 1 mL of EDTA plasma from the upper part of the tube and place in a plastic vial.
4. Send frozen.
Specimen Minimum Volume
Plasma: 0.5 mL
Specimen Stability Information
| Specimen Type | Temperature | Time |
|---|---|---|
| Plasma EDTA | Frozen | 28 days |
Reject Due To
| Gross hemolysis | Reject |
| Gross lipemia | Reject |
| Specimens other than EDTA plasma | Reject |
Day(s) Performed
Monday, Tuesday, Thursday
Report Available
4 to 7 daysMethod Name
Enzyme Immunoassay (EIA)
Reporting Name
Histamine PlasmaPerforming Laboratory
Eurofins ViracorSecondary ID
57533CPT Code Information
83088
Reference Values
0-1.0 ng/mL
Test Classification
This test was developed and its performance characteristics determined by Eurofins Viracor. It has not been cleared or approved by the U.S. Food and Drug Administration.SANFORD LABORATORY INTERFACE BUILD INFORMATION
| Result Code | Result Code Description |
|---|---|
| 2114 | Histamine |